Aube Thermostat How To Use: Easy Steps to Program Aube Thermostat

Did you know that Aube thermostats can control temperatures from a freezing -94°F to a scorching 248°F? That’s the kind of precision you get when learning how to use Aube thermostat systems in your home.

Whether you’re managing a basic baseboard heater or a complex HVAC system, these thermostats pack impressive features. They use advanced microprocessor technology with proportional integral adaptive control, specifically designed to enhance your comfort while maintaining efficient temperature management.

Getting started with your Aube thermostat might seem daunting at first. However, once you understand the basics – from programming daily schedules to setting up energy-saving modes – you’ll wonder how you ever managed without one.

In this guide, we’ll walk you through everything you need to know about programming and operating your Aube thermostat, ensuring you get the most out of its sophisticated features. Let’s make your home comfort control simpler and smarter!

Understanding Your Aube Thermostat

Aube thermostats combine precision engineering with user-friendly features, making them suitable for various heating systems. These devices stand out for their accurate temperature control, maintaining readings within one degree of true temperature.

Basic Components and Display

The heart of an Aube thermostat lies in its illuminated display screen, which shows essential information at a glance. The backlit display activates for 12 seconds when any button is pressed. A distinctive feature includes the heating power indicator, which displays the percentage of heating time required to maintain desired temperature.

The control interface consists of several key components:

  • Temperature adjustment buttons
  • Mode selection controls
  • Programming interface
  • Backlight button

The display shows both actual and setpoint temperatures, with the setpoint appearing for 5 seconds before switching to the measured temperature. Additionally, the system includes an ON/STANDBY switch for seasonal shutdown, enhancing security and energy efficiency.

Common Aube Thermostat Models

Aube offers three primary thermostat categories, each designed for specific applications:

  1. A-Model Series
    • Controls and displays ambient temperature
    • Ideal for general room temperature management
  2. F-Model Series
    • Specifically designed for floor temperature control
    • Uses external temperature sensors
    • Temperature range: 40°F to 104°F
  3. AF-Model Series
    • Combines ambient and floor temperature control
    • Maintains floor temperature within preset limits
    • Features dual-sensing capability

These models operate within specific parameters, with ambient temperature ranges from 40°F to 86°F. Furthermore, each thermostat includes advanced features like proportional integral adaptive (PIA) technology for enhanced comfort control.

The TH115 series, particularly popular among homeowners, offers three preset temperature modes:

  • Comfort temperature
  • Economy temperature
  • Vacation temperature

For specialized applications, models like the TH146 series accommodate various heating systems, including heat pumps and HVAC systems. Each unit comes with a comprehensive three-year warranty, demonstrating Honeywell Aube’s commitment to quality and reliability.

Initial Setup Steps

Setting up your Aube thermostat requires a few basic configurations to ensure optimal performance. Following these setup procedures will help you get started with your device.

Setting Time and Date

The clock setup process begins as soon as you power up your Aube thermostat, with the Time menu flashing on the screen. To set the current time and date:

  1. Press the DAY button to set the current day
  2. Use the HOUR button to adjust the hour
  3. Press the MIN button to set the minutes
  4. Press Mode/Ret to save your settings

For models with daylight savings capability, press and hold the Day button for 3 seconds until DLS appears on screen. Subsequently, use the arrow buttons to toggle between On (enabled) and Off (disabled).

Choosing Temperature Units (°F/°C)

Your Aube thermostat comes preset in Celsius mode. To modify the temperature display format, you have two options:

Method 1: Press and release the RESET button while holding down the MODE button.

Method 2: Press both Up and Down buttons for three seconds. The current format appears on screen. Use Up or Down button to switch between formats.

Display Brightness Adjustment

The display illumination features enhance visibility in various lighting conditions. The screen automatically lights up in these situations:

  • Pressing any button activates the backlight for 10 seconds
  • During temperature adjustment, the display shows the setpoint for 5 seconds
  • The backlight button specifically triggers a 5-second illumination

Moreover, the thermostat includes an automatic return feature for various functions like time recording and program settings. If you don’t complete these adjustments by pressing the RET key, the system automatically exits the mode.

For viewing the current temperature setpoint, press either of the adjustment buttons once. The setpoint appears for 5 seconds before returning to the actual temperature display. To adjust temperatures more quickly, press and hold the adjustment button to activate rapid scrolling.

Programming Daily Schedules

Programming your Aube thermostat unlocks its full potential through customizable daily schedules. The system comes with pre-configured settings that you can modify according to your comfort needs.

Weekday Programming

The default schedule divides each weekday into four distinct periods: Wake, Leave, Return, and Sleep. For Monday through Friday, these periods automatically activate at:

  • Wake: 6:00 AM at 70°F
  • Leave: 8:00 AM at 62°F
  • Return: 6:00 PM at 70°F
  • Sleep: 10:00 PM at 62°F

To modify these settings, press the PGM button to select the program you wish to adjust. Consequently, use the HOUR and MIN buttons to set the time, followed by temperature adjustments. First thing to remember, the thermostat automatically saves changes after 60 seconds of inactivity.

For enhanced flexibility, you can skip periods that don’t match your schedule. Alternatively, press the Up and Down buttons simultaneously when the hour or temperature is flashing. The display will show dashes (-) to indicate a skipped period.

Weekend Programming

Weekend schedules essentially differ from weekday programs, primarily focusing on Wake and Sleep periods. The default weekend schedule automatically skips the Leave and Return periods, acknowledging different routines for Saturdays and Sundays.

To program weekend schedules:

  1. Press the Day button to select Saturday or Sunday
  2. Press PGM to choose the period
  3. Set start times using Hour and Min buttons
  4. Adjust temperature settings as needed

In essence, the system offers two practical programming combinations for weekends:

  • “1 and 4” (Wake and Sleep)
  • “2 and 3” (Leave and Return)

The thermostat features an Early Start function that works exclusively with these combinations. For maximum efficiency, the system uses Comfort temperature settings during Wake and Return periods, while Economy settings activate during Leave and Sleep times.

Remember, you can create unique programs for each day. Each period can start at different times with varying temperatures. For seasonal adjustments, set the function switch to HEAT for heating programs or COOL for cooling programs.

Temperature Control Basics

Mastering temperature control on your Aube thermostat opens up a world of comfort customization options. The system offers multiple ways to manage your home’s climate effectively.

Setting Target Temperature

Initially, the display shows the actual measured temperature. To view your target temperature, press any adjustment button once, and the setpoint appears for 5 seconds. For quick adjustments, press and hold the button to activate rapid scrolling. The thermostat displays the percentage of heating time required to maintain your desired temperature, appearing as a numerical value when heating is activated.

Understanding Temperature Modes

Your Aube thermostat features several specialized temperature modes for different situations:

  • Automatic Mode: Follows your programmed schedule
  • Manual Mode: Maintains a fixed temperature indefinitely
  • Away Mode: Defaults to 59°F for energy savings
  • Countdown Mode: Temporary temperature for a set duration

Notably, the Countdown mode offers flexible timing options ranging from 15 minutes to 14 days. After the countdown ends, the thermostat automatically reverts to its previous mode.

Manual vs Auto Mode

The distinction between Manual and Auto modes lies in their operation principles. In Auto mode, the thermostat adheres to your programmed schedule, allowing for temporary overrides by pressing the Up or Down buttons. The override remains active until the next scheduled period, with “Auto” flashing on the display to indicate the temporary change.

Alternatively, Manual mode provides straightforward temperature control without schedule constraints. This mode maintains your selected temperature until you manually adjust it. To switch between modes:

  1. Press the Mode button to select your desired operation
  2. Use the adjustment buttons to set your preferred temperature
  3. The display confirms your selected mode

The thermostat incorporates a temporary override function in Auto mode. Primarily, this feature lets you modify the temperature without changing your programmed schedule. To cancel an override, simply press the Select button twice, returning to Automatic mode.

For extended absences, the Away mode offers enhanced energy savings. This mode locks in a default temperature of 59°F, which cannot be modified through regular temperature buttons. This feature serves dual purposes – protecting against frost while preventing unauthorized temperature adjustments during summer months.

The system’s proportional integral adaptive (PIA) technology ensures precise temperature control. This advanced feature calculates heating time percentages to maintain consistent comfort levels, displaying the active heating percentage on screen.

Advanced Programming Features

Beyond basic temperature control, Aube thermostats offer sophisticated programming capabilities designed for enhanced comfort and efficiency. These advanced features provide flexible control options for various situations.

Vacation Mode Settings

The Vacation mode serves as a powerful tool for managing your home’s climate during extended absences. This feature maintains a consistent temperature of 50°F (10°C), protecting your home while maximizing energy savings.

Activating Vacation mode can be accomplished through two distinct methods:

  1. Direct thermostat control – Press the dedicated vacation button, which displays a non-flashing icon
  2. Remote activation – Use an Aube telephone controller or compatible remote device

When activated remotely, the vacation icon flashes on the screen, and all thermostat buttons lock automatically. This security feature prevents unauthorized adjustments until the remote activation is canceled.

Energy-Saving Presets

The thermostat incorporates three preset temperature configurations, each tailored for specific scenarios:

Preset TypeA/AF ModesF ModePurpose
Comfort70°F (21°C)82°F (28°F)Home occupancy
Economy63°F (17°C)68°F (20°F)Sleep/away periods
Vacation50°F (10°C)50°F (10°C)Extended absence

To modify these energy-saving presets:

  1. Press the corresponding preset button to display current temperature
  2. Press and hold the same button until its icon appears
  3. Adjust to your preferred temperature

The system incorporates advanced temperature control mechanisms that minimize temperature variations. This precision helps reduce heating costs by maintaining optimal temperature levels throughout different periods. Furthermore, the thermostat displays the percentage of heating time required, providing visual feedback about energy consumption.

For maximum efficiency, the thermostat allows customization of heating cycles based on your specific system requirements. This adaptability ensures optimal performance across various heating systems, including:

  • Electric baseboard heaters
  • Radiant ceiling systems
  • Convector units

The thermostat’s armchair programming capability adds another layer of convenience, allowing you to remove the faceplate and program settings from any comfortable location. Additionally, the system features an automatic standby mode that activates at the end of heating seasons, providing enhanced security and energy conservation.

Customizing Comfort Settings

Personalizing your Aube thermostat settings unlocks a new level of home comfort control. The system’s microprocessor with proportional integral adaptive technology ensures precise temperature management while maximizing energy efficiency.

Day vs Night Temperature

The thermostat features three distinct preset temperatures designed for different times and situations. These presets include:

Time PeriodDefault SettingPrimary Use
Comfort70°F (21°C)Active hours
Economy63°F (17°C)Night/Away
Vacation50°F (10°C)Extended absence

To modify these presets, press the corresponding temperature button until its icon appears on screen. Afterward, adjust to your preferred temperature using the up or down buttons.

Creating Custom Programs

The thermostat supports up to four different programs per day. Hence, you can create unique temperature schedules that align perfectly with your daily routine. To set up custom programs:

  1. Press PGM to enter programming mode
  2. Press DAY to select specific days (hold for 3 seconds to select all days)
  3. Press PGM again to choose program number
  4. Use HOUR and MIN to set times
  5. Press CLEAR to remove unwanted time slots

Although you can program different schedules for each day, it’s often more efficient to start with the same schedule for the entire week and then modify exception days. The system automatically exits programming mode after 60 seconds of inactivity.

Override Functions

The thermostat offers flexible override options to accommodate unexpected schedule changes. In Automatic mode, temporary temperature adjustments remain active until the next programmed period. Therefore, the display flashes to indicate an active override.

For enhanced control, the system includes:

  • Remote input capabilities for telephone controllers
  • Automatic mode switching through remote signals
  • Vacation mode activation options

The remote control feature adds another layer of convenience through the CT240 telephone controller. Nevertheless, remember that remotely activated modes must be deactivated through the same method.

The P.I.A. controller minimizes temperature fluctuations by calculating the precise amount of power needed to maintain your desired temperature. This sophisticated approach ensures both comfort and efficiency, adapting to your heating system’s specific characteristics.

For maximum flexibility, you can skip periods that don’t match your schedule. Despite this flexibility, the Early Start feature works exclusively with specific period combinations – either periods “1 and 4” or periods “2 and 3”. This limitation ensures optimal temperature transitions throughout your day.

Maintaining Your Thermostat

Regular maintenance ensures optimal performance and longevity of your Aube thermostat. Proper upkeep not only extends the device’s lifespan but also maintains its accuracy and efficiency.

Battery Replacement

Your Aube thermostat comes equipped with two backup batteries that protect your programmed settings and clock during power outages. These batteries provide up to 500 hours of protection. For optimal performance, follow these battery replacement steps:

  1. Press the latch on the battery compartment
  2. Lift off the cover carefully
  3. Insert new batteries, respecting polarity markings
  4. Replace the compartment cover

To verify battery condition, press the BATT key – the display should show “BATT OK.” If “LO BATT” appears, replace the batteries immediately. For new thermostats displaying “LO BATT,” check battery polarity or adjust the contact on the battery cover.

Important Safety Note: Keep batteries away from children, as swallowing button cell batteries can be fatal.

Cleaning Tips

Properly maintaining your thermostat’s cleanliness significantly impacts its performance. A dirty thermostat can increase your fuel costs by up to 7%.

For electronic programmable thermostats:

  • Use a soft, non-abrasive cloth
  • Apply mild, ammonia-free cleaning solution
  • Keep moisture away from electronic components
  • Ensure air vents remain unobstructed

When cleaning the display screen, squeeze out excess liquid from cleaning cloths to prevent moisture accumulation. Some models feature a “Clean Screen” mode that deactivates the touchscreen for 30 seconds, allowing safe cleaning without accidentally changing settings.

For optimal maintenance results:

  • Check air vents monthly for blockages
  • Clean display surfaces weekly with disinfecting wipes
  • Inspect battery contacts quarterly
  • Verify temperature accuracy periodically

Environmental Consideration: At the end of your thermostat’s life cycle, dispose of it properly at authorized collection centers. This helps prevent negative environmental impact and protects human health.

The manufacturer provides a one-year limited warranty covering workmanship defects from the initial purchase date. This warranty excludes damage from improper installation or random damage post-installation. For warranty service, contact authorized service centers.

Remember to turn off power at the main electrical panel before performing any maintenance involving internal components. This precaution prevents electrical shock and ensures safe maintenance procedures.

Troubleshooting Common Issues

When encountering issues with your Aube thermostat, understanding common problems and their solutions helps maintain optimal performance. From display glitches to heating inconsistencies, most issues have straightforward fixes that you can implement without professional assistance.

Display Problems

Screen-related issues often stem from power or configuration problems. A blank display typically indicates one of several issues:

  • Dead or incorrectly installed batteries
  • Tripped circuit breaker
  • Corroded battery contacts
  • System power loss

For partial number displays where digits appear incomplete, check for these common causes:

  • Damaged LCD screen
  • Electronic component failure
  • Temperature sensor malfunction

Battery-Related Solutions:

  1. Remove and reinstall batteries
  2. Clean battery contacts with a brush or sandpaper
  3. Verify correct battery placement markings
  4. Replace with fresh batteries if “LO BATT” appears

When the display appears faded during heating activation, the system might be operating below its minimum load requirements. Generally, this indicates a mismatch between the thermostat and heating system specifications.

Heating/Cooling Issues

Temperature control problems typically manifest through several indicators:

Common Heating Problems:

  • Missing flame icon on display
  • Continuous heating without shutdown
  • System not responding to temperature adjustments
  • Incorrect temperature readings

For heating system failures, primarily check these elements:

  1. Verify the W wire connection remains secure
  2. Examine if the thermal protection device has activated
  3. Check for furniture or curtains blocking heaters

When the LP message appears and disappears after several minutes, this indicates the heater’s thermal protection has temporarily activated. Typically, this occurs due to:

  • Blocked heater vents
  • Overheating protection activation
  • Sensitive thermal protection settings

Reset Instructions

Occasionally, your Aube thermostat might require a reset to restore proper functionality. The reset process varies depending on your specific issue:

Standard Reset Procedure:

  1. Open the thermostat’s front panel
  2. Press and hold the Pgm button
  3. Insert a pointed object into the reset opening
  4. Wait for the screen to go blank
  5. Release the Pgm button after one second

For power-related resets:

  1. Remove the batteries
  2. Install them backwards for 10 seconds
  3. Reinstall correctly

Important: A complete reset returns all parameters to default settings, including:

  • Clock settings
  • Configuration options
  • Programmed schedules

For persistent issues, the thermostat might display error codes indicating specific problems:

Error CodeMeaningSolution
E1Temperature below 32°FHeating activates automatically
E2Temperature above 122°FCheck sensor connection
FLtFloor sensor faultVerify sensor wiring

Evidently, some problems might indicate more serious issues requiring professional attention. Contact customer service if:

  • The fault light remains on during normal operation
  • Reset procedures fail to resolve issues
  • Error codes persist after troubleshooting

For GFCI-equipped models, perform monthly tests to ensure proper operation. Ultimately, if test procedures fail:

  1. Cut power at the main electrical panel
  2. Contact authorized service personnel
  3. Avoid using the system until repaired

Presently, many modern Aube thermostats include self-diagnostic features that help identify problems. Obviously, maintaining proper documentation of error codes and troubleshooting steps helps track recurring issues and facilitates faster resolution when professional service becomes necessary.

Conclusion

Aube thermostats stand out as powerful tools for maintaining precise temperature control while saving energy. Their advanced features, from custom daily schedules to specialized modes like vacation settings, make home climate management effortless and efficient.

Programming these devices might seem complex at first, but mastering the basics leads to significant improvements in comfort and energy savings. Most importantly, regular maintenance and proper troubleshooting ensure your thermostat continues performing optimally for years.

The combination of user-friendly controls and sophisticated technology makes Aube thermostats excellent choices for both basic heating systems and complex HVAC setups. Therefore, taking time to understand your device’s capabilities will help maximize its potential and enhance your home comfort experience.

Remember, successful temperature management depends on proper setup, regular maintenance, and understanding your specific model’s features. Your comfort and energy savings will improve as you put these guidelines into practice.